MCP-E SeriesUser's Manual

Seite 2 - TABLE OF CONTENTS

9NOTE: The MCP 5000iE and 7000iE's AC input must be connected to an AC circut breakerwhich will provide for an emergency power off. (Must be per

Seite 3 - INTRODUCTION

10EnglishInstallation of the mounting tray and the stablizing feet.(Must be performed by Authorized Service Personnel ONLY)The MCP 5000iE and the MCP

Seite 4

11EnglishThe Tower Model allows the user to install the UPS next to the tower computer. UseCAUTION, the UPS is extremely heavy. Place the UPS in the

Seite 5 - CONTROLS AND INDICATORS

12CONNECTING TO AN AC SOURCEPlug the UPS into a two pole, three wire, grounded receptacle only. Do not use extensioncords, adapter plugs, power strip

Seite 6

13TURNING THE UNIT ON/OFFThe UPS is shipped with the unit disabled. Turn dip switch #1 to the ON position beforeattempting to turn on the unit. This

Seite 7 - INSTALLATION

14EnglishEnglishConfiguration Switches for the MCP 2000/3000/5000/7000. The "System Enable" switchmust be enabled for the UPS to operate.MC

Seite 8 - MCP 5000iE and MCP 7000iE

15EnglishEnglishPress and release the main power switch on the front of the unit to turnon the unit. Press and release again to turn off the unit.

Seite 9

16Communications port information for 2KVA, 3KVA, 5KVA and 7KVA units only:These units contain two independent communications ports. Port one is for

Seite 10 - Service Personnel ONLY)

17Possible CauseSymptom What To DoTROUBLESHOOTINGE10 is displayed afterturning on unitConfiguration dip switch is inthe off positionTurn Dip Switch #1

Seite 11

18Code DefinitionE01 System off resulting from Microprocessor checksum error.E03 Battery voltage is below safe operating range (AC mode).E04 Battery v

Seite 12

1© Copyright Para Systems, Inc., 2001MCP-E SeriesUser's Manual1. Introduction 22. Controls and Indicators 43. Installation 64. Operation 135. Tr

Seite 13 - ONNECTING YOUR EQUIPMENT

19Diagnostic Error Codes for 2KVA, 3KVA, 5KVA, 7KVA unitsError DescriptionE00 System ROM checksum error.E01 System RAM data read/write error.E02 Syste

Seite 14 - OPERATION

20REPLACING THE BATTERY(Must be performed by Authorized Service Personnel ONLY)The Tower Series UPS has a replacable battery(s), however the unit must

Seite 15 - EnglishEnglish

21CAUTION:System voltages range from 24 VDC to 288 VDC. A battery can present arisk of electrical shock and high short circuit current. The followin

Seite 16 - LOW BATTERY WARNING

22Battery Replacement Procedure for Tower Model(Must be performed by Authorized Service Personnel ONLY)PLEASE READ THE CAUTIONS BEFORE ATTEMPTING TO R

Seite 17

23Battery Replacement Procedure for Rack Mount Models(Must be performed by Authorized Service Personnel ONLY)PLEASE READ THE CAUTIONS BEFORE ATTEMPTIN

Seite 18 - TROUBLESHOOTING

24OBTAINING SERVICEIF THE UPS REQUIRES SERVICE1.Use the TROUBLESHOOTING section to eliminate obvious causes.2.Verify there are no circuit breakers tri

Seite 19

25SPECIFICATIONS NOTE: 230Vac Specs Shown In ( )500W700W 2100W3500W4900W36VDC 7.2Ah 288VDC 7.2Ah72VDC 7.2Ah1400W96VDC 7.2Ah 240VDC 7.2Ah100,110,115,1

Seite 20

26(These items may require optional software or hardware)FUNCTION FACTORY DEFAULT DESCRIPTIONUSER CHOICESEnglishEnglishCONFIGURABLE PARAMETERS AND S

Seite 21 - REPLACING THE BATTERY

27Customized Output Receptacle PanelsThe MCP-E series UPS has a replacable receptacle panel. The receptacle panel can beconfigured with multiple choi

Seite 22 - CAUTION:

28LIMITED PRODUCT WARRANTYPara Systems Inc. (Para Systems) warrants this equipment, when properly appliedand operated within specified conditions, aga

Seite 23

2Thank you for purchasing a MINUTEMAN™ power protection product. It has beendesigned and manufactured to provide many years of trouble free service.P

Seite 24

29EnglishDECLARATION OF CONFORMITYApplication of Council Directive(s): 89/336/EEC, 7/23/EECStandard(s) to which Conformity is declared: EN50091-1, EN5

Seite 25 - OBTAINING SERVICE

32Notes:EnglishEnglish30

Seite 26 - SPECIFICATIONS

Para Systems, Inc.1455 Lemay Dr.Carrollton, TX 75007Phone: 972-446-7363800-238-7272Fax: 972-446-9011Quickfax: 800-263-3933Internet: minutemanups.comPN

Seite 27 - AND SETTINGS

3WARNING: Risk of electrical shock. Hazardous live parts insidethis power supply are energized from the battery even when the ACinput power is di

Seite 28

4Primary Power Switch: Press and release theON/OFF button to turn the unit ON or OFF.Normal Mode Icon: This icon will illuminatewhen the utility powe

Seite 29 - LIMITED PRODUCT WARRANTY

5English!Unit Input Icon: When selected, this will display the selecteditem for the input from utility.Unit Output Icon: When selected, this will di

Seite 30 - Robert Calhoun

6REAR PANEL (120Vac models shown)INSTALLATION PLACEMENTInstall the UPS in a temperature controlled environment that is free of conductive contami-na

Seite 31

7EnglishMCP 5000iE and MCP 7000iE1. Fans: Internal Cooling Fans.2. Maintenance Bypass Switch: In normal operation the switch must be in the UPS positi

Seite 32

8MCP 5000iE and MCP 7000iE Input/Output/Battery Pack Connections(Must be performed by Authorized Service Personnel ONLY)Installation instructions for